Batam Medical Shop

VitalCare 506LNVP3 w/ Nellcor Sp02, NIBP, TurboTemp, Printer, HR

On sale On sale!
$1,600.00 tax incl.

Loyalty program By buying this product you can collect up to 160 reward points as a voucher of $160.00. Your reward points.



Features and Benefits

  • Proprietary ComfortCuff ™ NIBP measures on inflation for faster, more comfortable readings.
  • Choice of Criticare DOX™ digital SpO2 technology or Nellcor OxiMax™ SpO2 technology.
  • Audible and visual alarms are adjustable providing instant notification the way you need them.
  • Optional FILAC FasTemp™ predictive temperature for quick, accurate measurements.
  • Optional internal printer for on-demand, automatic interval, trends or multi-patient reports.

Technical Specifications

Non-Invasive Blood Pressure

  • Technique: Oscillometric measure upon inflation.
  • Measurement Time: <40 seconds typical; 0 to 300mmHg;
  • Standard adult cuff.
  • Automatic Measurement.
  • Cycles: 1 - 60 minute; 2 - 4 hour; STAT.
  • Inflation Pressure Range: 30 to 300mmHg (Adult)
  • 30 to 150mmHg (Pediatric)
  • 20 to 150mmHg (Neonate)
  • Resolution: 1mmHg.
  • Clinical Accuracy: SP-10:2002.
  • Transducer Accuracy: ±2mmHg or ±2% of reading, whichever is greater, over full range.
  • STAT mode: 5 minutes of consecutive readings.

Pulse Oximetry

  • Range: 1% to 99%
  • Resolution: 1%
  • Accuracy (DOX only): 70% to 99% range: ±2%;
  • 50% to 69% range: ±3%; <50%: unspecified
  • Accuracy (OxiMax Only): 70% to 99% range: ±2%; <70%: unspecified
  • Method: Dual wavelength LED
  • Audio: Tone with each detected pulse; pitch varies with saturation

Heart (Pulse) Rate

  • Range: 20 to 300bpm.
  • Accuracy (DOX only): Greater of ±1bpm or ±1%, of reading.
  • Unspecified for <30 or >240 bpm.
  • Accuracy (OxiMax only): Greater of ±1bpm or ±1%, of reading.
  • Unspecified for <30 or >240 bpm.
  • Update Time: Every second.
  • Resolution: 1bpm.
  • Pulse Volume: 10 levels or Off.

Temperature (optional)

  • Type: Alaris TurboTemp®Method: Predictive or ContinuousChannels: 1
  • Predictive Mode Range: 96.0° to 106° F (35.6°> to 41.1°C)
  • Continuous Mode Range: 80:0° to 106° F (26.7° to 41.1° C)
  • Accuracy:  ±0.2°F (±0.1°C) (measured in calibrated water bath in continuous mode)
  • Resolution: 0.1° F or 0.1° C
  • Response Time: 10 seconds typical (oral measurements)
  • Probes:  CAT1544 Oral, CAT 1545 Rectal 
  • Probe Covers:  CAT 447 (P850A)

Alarms

  • Indication: Audible; Visual
  • Volume: 10 levels or Off
  • Silence: Yes; 2 minutes or permanent

Trend Memory

  • Memory: Last 24 hours
  • Parameters: SpO2, pulse rate, NIBP, temperature
  • Report Types: Single Patient or Multi-patient;
  • Selectable formats

Displays

  • Type: LED
  • Parameters: NIBP, SpO2; temperature, pulse rate; pulse bar
  • Status: Alarm Silence; Sensor; Low Battery; External
  • Power; Patient Size
  • Text: Alphanumeric LCD
  • Languages: English, French, German, Italian, Portuguese, Spanish, Dutch, Danish

System Output

  • Com Port: Serial, RS 232-compatible

Printer

  • Type: Thermal array
  • Tabular Mode: 1 - 60 minute intervals; 2 - 24 hour intervals;
  • Auto on BP; Auto on Alarm, Off

Mechanical

  • Weight: Base unit with battery: 6.95 lb; 3.15kg
  • Size: Base unit: 8.7" (H) x 7.1" (W) x 6.5” (D); 22cm (H) x 18cm (W) x 16.5cm (D)

Power Requirements

  • Voltage: 100 to 240 VAC, 50 to 60 Hz
  • Battery: Sealed lead acid; Life: 8 hours
  • Rechargeable: 6 hours

Environmental

  • Operating Temperature: 32º to 113º F; 0º to 45º C
  • Storage Temperature: 23º to 122º F; -5º to 50º C
  • Operating Humidity: 15% to 90%, non-condensing

Classification

  • Type of Protection: Class I equipment
  • Degree of Protection: Type CF defibrillator-proof equipment
  • Protection against Ingress: IPX1 rating, Drip-Proof Equipment

 

Cart  

(empty)

New products

No new product at this time

Batam Medical Shop is an Upfront Merchant on TheFind. Click for info.